Outcome | Not compliant |
6 violations cited :
Code 5-202.13
Air gap between supply line and flood rim of not provided
FULL FOOD CODE:
An air gap between the water supply inlet and the flood level rim of the PLUMBING FIXTURE, EQUIPMENT, or nonFOOD EQUIPMENT shall be at least twice the diameter of the water supply inlet and may not be less than 1 inch. (P)
An air gap between the water supply inlet and the flood level rim of the PLUMBING FIXTURE, EQUIPMENT, or nonFOOD EQUIPMENT shall be at least twice the diameter of the water supply inlet and may not be less than 1 inch. (P)
Priority
Not corrected
Code 6-501.12
Physical facilities/structures floors cleaned when food items are exposed
FULL FOOD CODE:
(A) PHYSICAL FACILITIES shall be cleaned as often as necessary to keep them clean. (B) Except spill cleanup, cleaning shall be done during periods when the least amount of FOOD is exposed such as after closing.
(A) PHYSICAL FACILITIES shall be cleaned as often as necessary to keep them clean. (B) Except spill cleanup, cleaning shall be done during periods when the least amount of FOOD is exposed such as after closing.
Core
Not corrected
Code 4-204.11
Exhaust ventilation hood system(s) designed to allow grease or condensation from draining dripping onto equipment
FULL FOOD CODE:
Exhaust ventilation hood systems in FOOD preparation and WAREWASHING areas including components such as hoods, fans, guards, and ducting shall be designed to prevent grease or condensation from draining or dripping onto FOOD, EQUIPMENT, UTENSILS, LINENS, and SINGLE-SERVICE and SINGLE-USE ARTICLES.
Exhaust ventilation hood systems in FOOD preparation and WAREWASHING areas including components such as hoods, fans, guards, and ducting shall be designed to prevent grease or condensation from draining or dripping onto FOOD, EQUIPMENT, UTENSILS, LINENS, and SINGLE-SERVICE and SINGLE-USE ARTICLES.
Core
Not corrected
Code 5-205.15
Drainage system drain lines not constructed designed installed according to law
FULL FOOD CODE:
A PLUMBING SYSTEM shall be: (A) Repaired according to LAW; (P) and (B) Maintained in good repair.
A PLUMBING SYSTEM shall be: (A) Repaired according to LAW; (P) and (B) Maintained in good repair.
Core
Not corrected
Code 4-501.11
Equipment in poor repair
FULL FOOD CODE:
EQUIPMENT shall be maintained in a state of repair and condition that meets the requirements of the code.
EQUIPMENT shall be maintained in a state of repair and condition that meets the requirements of the code.
Core
Not corrected
Code 6-201.15
Mat(s)/duckboard(s) not easily cleanable
FULL FOOD CODE:
Mats and duckboards shall be designed to be removable and EASILY CLEANABLE.
Mats and duckboards shall be designed to be removable and EASILY CLEANABLE.
Core
Not corrected